欢迎访问上海峰志仪器有限公司官网!
上海峰志仪器有限公司shanghai fengzhi instrument co,.ltd
全国咨询热线:13818683556
您的位置:首页>>生命科学资讯

GFP Fluorescence flashlight LUYOR-3280UV

作者: 时间:2020-01-19 10:07:44浏览1198 次

信息摘要:

LUYOR-3280UV gfp flashlight( GFP Fluorescence Flashlight),LUYOR 提供多种便携式紫外光源,用于检测和可视化绿色荧光蛋白 (GFP),绿色荧光蛋白 (GFP) 在细胞或细胞提取物中表达时会发出亮绿色荧光。

LUYOR-3280UV gfp flashlight

LUYOR-3280 Fluorescence Excitation Flashlights 

LUYOR 提供多种便携式紫外光源,用于检测和可视化绿色荧光蛋白 (GFP),绿色荧光蛋白 (GFP) 在细胞或细胞提取物中表达时会发出亮绿色荧光。

LUYOR-3280UV gfp flashlight

紫外线笔灯

这款袖珍型一次性灯具有照亮您的实验所需的功率。该波长针对绿色荧光蛋白活性进行了优化,包括细菌转化、GFP 色谱和 Secrets of the Rainforest 试剂盒。

LUYOR-3280UV长波紫外线灯

这款方便的手持式长波紫外线灯使用锂电池组供电,波长输出介于 300 和 400 nm 之间。该灯专为 GFP 激发而设计,非常适合与 pGLO 细菌转化、GFP 色谱和 Secrets of the Rainforest 试剂盒一起使用。丙烯酸安全罩保护灯泡和用户的眼睛。

3280-tSS.jpg

LUYOR-3280UV gfp flashlight

LUYOR offers two portable sources of UV light for detecting and visualizing green fluorescent protein (GFP), which fluoresces brilliant green when expressed in cells or cell extracts.

未命名-1.jpg

LUYOR-3280UV gfp flashlight

This pocket-size disposable lamp has the power needed to illuminate your experiments. The wavelength is optimized for green fluorescent protein activities, including LUYOR's pGLO™ bacterial transformation, GFP chromatography, and Secrets of the Rainforest™ kits.


Long-Wave UV Lamp

3280GR2.jpg

This convenient handheld long-wave UV lamp runs on four AA batteries and has a wavelength output between 300 and 400 nm. Designed for excitation of GFP, this lamp is ideal for use with LUYOR's pGLO bacterial transformation, GFP chromatography, and Secrets of the Rainforest kits. The acrylic safety shield protects the bulb and the user’s eyes.

3280-1.png


Blue Green LED Technology

Visualize your gel with the new LUYOR-3280UV/GR Blue/Green LED Flashlight. It is equipped with the same Blue/Green LED technology used in the LUYOR-3280UV/GR Blue/Green Transilluminator. The LUYOR-3280UV/GR Blue/Green Flashlight has all the benefits from the LED light, such as harmless to your skin and to your DNA sample, as well as the signal intensity previously only seen on UV-light transilluminators.

GFP Fluorescence Flashlight

Detect GFP-Transfections

Additionally, it is possible to detect GFP expression without the use of the harmful UV-light. The light of the LEDs is able to ultrapass tissues enabling the detection of internally expressed GFP (see below).


The LUYOR-3280UV/GR Blue/Green LED Flashlight is suitable for research use only.

The LUYOR-3280UV/GR Blue/Green LED Flashlight must be used by specialized personnel that know the health risks associated with blue/green light irradiation and with the reagents that are normally used with this instrument. Human naked eyes with long time irradiation of blue/green light may have the probability of suffering from retina diseases. The amber filter provides blue/green light protection. However, it does not guarantee complete protection. It is designed to shield the person working at the LED Flashlight only.


WARRANTY

The LUYOR-3280UV/GR Blue/Green LED Flashlight is warranted against defects in materials and workmanship for 1 year. If any defects occur in the instrument or accessories during this warranty period, LUYOR instrument co,.ltd will repair or replace the defective parts at its discretion without charge. The following defects, however, are specifically excluded:

1. Defects caused by improper operation.

2. Repair or modification done by anyone other than LUYOR instrument co,.ltd or an authorized agent.

3. Damage caused by substituting alternative parts.

4. Use of fittings or spare parts supplied by anyone other than LUYOR instrument co,.ltd.

5. Damage caused by accident or misuse.

6. Damage caused by disaster.

7. Corrosion caused by improper solvent or sample.

For any inquiry or request for repair service, contact your local LUYOR instrument co,.ltd office. Inform LUYOR instrument co,.ltd of the model and serial number of your instrument.


REGULATORY NOTICE

IMPORTANT:

 This instrument is designed and certified to meet safety standards and EMC regulations.

Certified products are safe to use when operated in accordance with the instruction manual. This instrument should not be modified or altered in any way. Alteration of this instrument will:

1. Void the manufacturer’s warranty

2. Void the safety and EMC certification

3. Create a potential safety hazard 


LUYOR instrument co,.ltd is not responsible for any injury or damage caused by the use of this instrument for purposes other than those for which it is intended, or by modifications of the instrument not performed by LUYOR instrument co,.ltd or an authorized agent.


IMPORTANT NOTICE

Please, read the installation instruction carefully before using the LUYOR-3280UV/GR Blue/Green LED Flashlight. This instrument is intended for research laboratory use and it must be operated only by specialized personnel aware of the potential risks associated with the chemical and biological agents normally used with this unit. This instrument is meant for use only by specialized personnel that know the health risks associated with blue/green light radiation and with reagents that are normally used with this instrument.

The amber filter provides some blue light protection. However, it does not guarantee complete protection, and it is designed to shield only the person working in front of the system, also to observe the DNA gel fluorescence emission clearly. 


GENERAL PRECAUTIONS

➢ Do not look at the blue/green light directly without protective gear!

➢ Do not use the instrument continously for longer than 10 minutes to prevent overheating.

➢ Plug the LUYOR-3280UV/GR Blue/Green LED Flashlight on an electric line with ground connection during usage.

➢ Do not pour liquids directly on the LUYOR-3280UV/GR Blue/Green LED Flashlight.

➢ Switch off the instrument immediately after its use.

➢ Position the LUYOR-3280UV/GR Blue/Green LED Flashlight to prevent harm to nearby operators.


3280UV.png